Features
- The pop-off valve plays a crucial role as a secondary pressure relief valve.
- This pop-off valve has a stainless steel body and NBR O-rings.
- It is designed to work together with a primary pressure regulating valve, such as a pressure regulator or unloader valve.
- The pop-off valve should be set to open at approximately 200 PSI above the primary pressure control valve’s adjusted pressure.
- In the event of a primary valve failure, this secondary valve will bypass fluid to protect the operator’s safety and the integrity of the high-pressure pumping system.
Specifications
- Max Flow: 189 L/min
- Max Pressure: 1,750 PSI
- Inlet Port Size: 1″ NPT M
- Discharge Port Size: 1 1/2″ Barb
- Accessory Type: Pop-Off Valves
- Material: 316 Stainless Steel
- By-Pass Port: 1 1/2″ Barb